XTR-12400
|
Range | 25-40A |
Contact configuration | 2 CO (DPDT) |
Nominal coil power | AC 1.8 VA / DC 1.2W |
Coil voltage range | (0.8 . . . 1.1)Un |
Holding voltage AC/DC | 0.8/0.5 Un |
Drop-out voltage AC/DC | 0.2/0.1 Un |
Rated contact voltage | 250 V AC |
Rated contact current | 10 A |
Operating frequency | 50 Hz |
Max. Switchin power AC1 | 2500 VA |
Nominal coil voltage Un (V AC) | 12, 24, 48, 110, 230 |
Nominal coil voltage Un (V DC) | 12, 24, 48, 110 |
Operate/release time max. | 12/10 ms |
Dielectric strength | 2000 V AC, between coil-contact |
1500 V AC, NO contact | |
2000 V AC, between pole-pole | |
Insulation resistance | 10 M Ohm min. (at 500 V DC) |
Contact resistance | 50 m Ohm max. (initial value) |
Operating frequency (no load) | 300 operations/min |
Operating frequency (full load) | 10 operations/min |
Mechanical durability | 10.000.000 operations min. |
Electrical durability | 100.000 operations min. |
Degree of protection | IP40 |
Ambient operating temperature | -10 . . . 55°C |
Ambient operating humidity | 85%RH max. |
Terminals | Socket pin |
Contacts | Silver alloy (Ag/Ni) |
Standarts | EN 61810-1 |
Approval | CE |
Storage temperature | -40 . . . 70°C |